So how exactly does my fridge water line connect with the valve?

I happened to be shipped a new whirlpool fridge today. I experienced an existing 1/4 ” copper pipe that I utilized as a water supply line.

We slice the copper pipe having a pipe cutter, and I also slipped a compression nut and sleeve at risk. We slid the pipe in to the water inlet valve and tightened the compression nut.

After turning on water (and confirming no leakage) a gallon was run by me of water out of the front side dispenser. Instantly, the fitting to that we connected the compression nut popped from the valve and sprayed water all over. Evidently, there’s nothing to carry this fitting in there. Have always been we doing something very wrong, or perhaps is the valve faulty?

The compression nut will not leak at all, and also the water moves efficiently out from the fitting if it is eliminated like in the 2nd photo.

Here is the view in the valve in which the fitting plugs in. You can view the display screen in there that prevents debris. I do not see any such thing addressing it.

Up-date: as you can plainly see in the picture that is second there was a lip that one thing into the green valve is supposed to seize. I am able to see two steel teeth in the valve that is green probably retract to seize the lip. Unfortuitously, I do not see any method of making them retract. The cover that is blue the leading is much like a general general public restroom screw: it really is slotted so that it is screwed on although not down.

2 Answers 2

Sorry to possess squandered individuals time, but a lot was learned by me. The specialist arrived, while the response ended up being that the valve ended up being faulty. The parts that are inner were clamped tightly round the lip through the production procedure.

In order to connect into the ice box:

1) Remove the cap that is plastic water valve inlet slot. Connect the copper pipe into the valve inlet making use of a compression sleeve and nut as shown. Fasten the compression nut. Usually do not overtighten. Pull regarding the copper tubing to ensure that it’s safe.

2) Create a site cycle, and employ unique care to avoid kinks. Secure copper tubing towards the fridge cabinet having a “P” clamp.

3) switch on water supply to your fridge, and always check for leakages. Correct any leakages.

ESSENTIAL: Don’t overtighten.

After linking the fridge to a water supply or changing water filter, flush the water system. Work with a sturdy container to depress and keep the water dispenser lever for 5 moments, and then launch it for blackchristianpeoplemeet 5 moments. Perform until water starts to move. As soon as water starts to flow, carry on depressing and releasing the dispenser lever (5 moments on, 5 seconds off) until a complete of 4 gal. (16 L) happens to be dispensed. This will flush atmosphere through the filter and water dispensing system, and prepare the water filter for use. Extra flushing might be expected in a few households. As atmosphere is cleared through the system, water may spurt from the dispenser.

Look for sufficient water force. you ought to be in a position to dispense about 3 to 6 ounces in 5 moments.

In the event that fridge won’t have a dispenser, check out the water force with the water supply line, if at all possible. The Вј” water supply line should dispense at the very least 9 ounces of water in 5 moments.

I am guessing the “P” clamp ensures the pipeline remains put. I mightn’t think water stress will be able to displace the fitting, but that knows possibly it is a design flaw or faulty component. In either case the “P” clamp should contain the supply line set up.

I will head out on a limb right right right here, and imagine the pipeline arrived disconnected throughout your test once you stopped water that is dispensing? This might be due to water hammer, this is certainly a common issue with fast acting solenoids ( perhaps perhaps perhaps Not the hose popping down, water hammer bit). Should this be the truth, the “P” clamp should counteract the forces being making the pipe pop from the socket by maybe not enabling the pipeline to go.

EDIT:

As a result to your up-date. Decide to try pushing the fitting in (type of difficult), the metal hands could be involved only if the fitting is correctly seated and pressed in far sufficient.